Barik, RK and Raju, RS and Das, S and Rathore, S (2011) Design and Development of Thermionic Emission Microscope. In: International Vacuum Electronics Conference (IEEE-IVEC 2011), February 21-24, 2011, Bangalore, India. (Submitted)
|
PDF
- Submitted Version
Download (583Kb) | Preview |
Abstract
Thermionic Emission Microscope (THEM) developed at CEERI has an electrostatic immersion lens to magnify the image. The geometry of lens and potentials are optimized to achieve a magnification of about 15 times with a clear image. The design of deflection plates and lens are carried out using OmniTRAK 3-D to ensure required deflection of beam without losing laminarity and beam interception with plates. Faraday cage, containing a narrow aperture, is designed to obtain elemental currents with low secondary emission. The emission picture of a B-Type cathode has been obtained. The results are satisfactory.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Uncontrolled Keywords: | THEM, OmniTRAK, Dispenser cathode |
Subjects: | ?? TK ?? Microwave Tubes > Cathodes |
Divisions: | Microwave Tubes |
Depositing User: | Mr. Rabin Chatterjee |
Date Deposited: | 21 May 2013 04:41 |
Last Modified: | 21 May 2013 04:41 |
URI: | http://ceeri.csircentral.net/id/eprint/122 |
Actions (login required)
View Item |