Thermal and Structural Analysis of Depressed Collector for 42 GHz Gyrotron

Bhattacharya, R and Sahu, NK and Goswami, U and Khatun, H and Singh, U and Sinha, AK (2012) Thermal and Structural Analysis of Depressed Collector for 42 GHz Gyrotron. In: National Conference on Materials, Devices and Circuits in Communication Technology (MDCCT - 2012), February 6 - 7, 2012, Burdwan, India. (Submitted)

[img]
Preview
PDF - Submitted Version
Download (307Kb) | Preview

Abstract

Thermal and structural analysis of depressed collector for 42 GHz gyrotron and the effect of structural deformation is presented. Finite element analysis codes ANSYS have been used for the thermal and the structural simulation. The values of the water flow rate and the hydraulic diameter have been optimized.

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: Gyrotron, depressed collector, thermal & structural analysis,